Numerical Study on the Reduction of Recirculation Using Sealed Cold Aisles and its Effect on the Efficiency of the Cooling Infrastructure

[+] Author Affiliations
Mahmoud Ibrahim, Bahgat Sammakia, Bruce Murray

Binghamton University, Binghamton, NY

Siddharth Bhopte

Microstaq Incorporation, Austin, TX

Madhusudan Iyengar, Roger Schmidt

IBM Corporation, Poughkeepsie, NY

Paper No. IPACK2011-52166, pp. 585-593; 9 pages
doi:10.1115/IPACK2011-52166
From:
  • ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems
  • ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems, MEMS and NEMS: Volume 2
  • Portland, Oregon, USA, July 6–8, 2011
  • ISBN: 978-0-7918-4462-5
  • Copyright © 2011 by ASME

abstract

The increase in computing performance of electronic equipment is causing higher power consumption and in turn higher heat dissipation. On the larger scale, data centers that house hundreds of these individual electronic equipment are foreseeing an inevitable increase in heat dissipation on a facility level. The cooling cost of these rooms is becoming a major challenge, where a specified inlet temperature must not be exceeded in order to insure the safe and reliable operation of the electronic equipment. Most of the data centers in use today adopt the hot aisle-cold aisle configuration, where air is supplied through a plenum. The major problem with this configuration is the mixing of cold supply air from the tiles with hot exhaust air from the servers. This affects the efficiency of the cooling infrastructure and in turn affects the cost of operation. This study concentrates on the idea of sealing the cold aisle. Completely sealing the cold aisle is not practical due to pressure and noise problems, and therefore a perforated ceiling is proposed. A parametric study is generated to look at the effects of perforated ceiling resistance and different CRAC (Computer Room Air Conditioning) airflow supply percentage on the inlet temperature of the racks. A metric is proposed to quantify the variation of inlet temperature across the height of a rack and for a given cold aisle.

Copyright © 2011 by ASME
Topics: Cooling

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In