From Chip to Cooling Tower Data Center Modeling: Chip Leakage Power and its Impact on Cooling Infrastructure Energy Efficiency

[+] Author Affiliations
Thomas J. Breen, Ed J. Walsh, Jeff Punch

Stokes Institute, University of Limerick, Limerick, Ireland

Amip J. Shah, Cullen E. Bash

Hewlett Packard Company, Palo Alto, CA

Niru Kumari

Hewlett-Packard Company, Palo Alto, CA

Tahir Cader

Hewlett Packard Company, Liberty Lake, WA

Paper No. IPACK2011-52030, pp. 433-442; 10 pages
doi:10.1115/IPACK2011-52030
From:
  • ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems
  • ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems, MEMS and NEMS: Volume 2
  • Portland, Oregon, USA, July 6–8, 2011
  • ISBN: 978-0-7918-4462-5
  • Copyright © 2011 by ASME

abstract

The power consumption of the chip package is known to vary with operating temperature, independently of the workload processing power. This variation is commonly known as chip leakage power, typically accounting for ∼10% of total chip power consumption. The influence of operating temperature on leakage power consumption is a major concern for the IT industry for design optimization where IT system power densities are steadily increasing and leakage power expected to account for up to ∼50% of chip power in the near future associated with the reducing package size. Much attention has been placed on developing models of the chip leakage power as a function of package temperature, ranging from simple linear models to complex super-linear models. This knowledge is crucial for IT system designers to improve chip level energy efficiency and minimize heat dissipation. However, this work has been focused on the component level with little thought given to the impact of chip leakage power on entire data center efficiency. Studies on data center power consumption quote IT system heat dissipation as a constant value without accounting for the variance of chip power with operating temperature due to leakage power. Previous modeling techniques have also omitted this temperature dependent relationship. In this paper we discuss the need for chip leakage power to be included in the analysis of holistic data center performance. A chip leakage power model is defined and its implementation into an existing multi-scale data center energy model is discussed. Parametric studies are conducted over a range of system and environment operating conditions to evaluate the impact of varying degrees of chip leakage power. Possible strategies for mitigating the impact of leakage power are also illustrated in this study. This work illustrates that when including chip leakage power in the data center model, a compromise exists between increasing operating temperatures to improve cooling infrastructure efficiency and the increase in heat load at higher operating temperatures due to leakage power.

Copyright © 2011 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In