0

Full Content is available to subscribers

Subscribe/Learn More  >

Efficient and Reliable Operation of Air-Side Economizers Using Extremum Seeking Control

[+] Author Affiliations
Pengfei Li, Yaoyu Li

University of Wisconsin at Milwaukee, Milwaukee, WI

John E. Seem

Johnson Controls, Inc., Milwaukee, WI

Paper No. DSCC2008-2240, pp. 1011-1018; 8 pages
doi:10.1115/DSCC2008-2240
From:
  • ASME 2008 Dynamic Systems and Control Conference
  • ASME 2008 Dynamic Systems and Control Conference, Parts A and B
  • Ann Arbor, Michigan, USA, October 20–22, 2008
  • Conference Sponsors: Dynamic Systems and Control Division
  • ISBN: 978-0-7918-4335-2 | eISBN: 978-07918-3838-9
  • Copyright © 2008 by ASME

abstract

For the heating, ventilating, and air conditioning (HVAC) systems for commercial buildings, there has been a greater demand for reducing energy consumption. The economizers have been developed as a class of energy-saving HVAC devices that may increase the energy efficiency by taking advantage of outdoor air during cool or cold weather. However, many economizers do not operate in the expected manner and waste even more energy than before installation, mostly due to the unreliable sensors and actuators in practice. Better control strategy is needed for optimal and robust operation. In this paper, an extremum seeking control (ESC) based self-optimizing strategy is proposed to minimize the energy consumption, with the feedback of chilled water supply command rather than the temperature and humidity measurements. The mechanical cooling load is minimized by seeking the optimal outdoor-air damper opening in real time. Such scheme does not need temperature and humidity sensors and depends much less on the knowledge of economizer model. Simulation was performed on a Modelica based transient model of a single-duct air-handling unit (AHU) developed with Dymola and AirConditioning Library. The simulation results demonstrated the potential of using ESC to achieve the minimal mechanical cooling load in a self-optimizing manner. In addition, an anti-windup ESC scheme is proposed to handle the ESC windup due to actuator (damper) saturation. The simulation results validated the effectiveness of the proposed anti-windup ESC.

Copyright © 2008 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In