0

Full Content is available to subscribers

Subscribe/Learn More  >

Simulation of Heat Transfer in Bridge-Based Micro Calorimeters

[+] Author Affiliations
Jun Yu, Zhen’an Tang, Zhengxing Huang, Chong Feng

Dalian University of Technology, Dalian, China

Paper No. ICNMM2009-82224, pp. 1179-1183; 5 pages
doi:10.1115/ICNMM2009-82224
From:
  • ASME 2009 7th International Conference on Nanochannels, Microchannels, and Minichannels
  • ASME 2009 7th International Conference on Nanochannels, Microchannels and Minichannels
  • Pohang, South Korea, June 22–24, 2009
  • Conference Sponsors: Nanotechnology Institute
  • ISBN: 978-0-7918-4349-9 | eISBN: 978-0-7918-3850-1
  • Copyright © 2009 by ASME

abstract

Previous studies of bridge-based micro calorimeters have shown that these devices can measure heat capacity and melting point of ultra thin films with pulse scan calorimetry. The bridge-based micro calorimeters consist of a sample region and several beams that connecting the sample region with silicon substrate. Both the sample region and the beams are suspending on the silicon substrate for thermal isolation. The temperature distribution of the micro calorimeter during a heating pulse depends on the joule-heating of the heating resistor, the heat absorption and heat conduct of the bridge. The heat transfer through the beams during a pulse scan measurement is complex because there is heat generation on some beams and the temperature distribution along the beams is not uniform. Using three dimensional finite element analyses (FEA), the thermal-electrical simulations of the heat transfer in the bridge-based micro calorimeters have been performed. The heat consumption and temperature distribution at steady state analyses, the temperature response of the bridge and the heat generation of the heater at transient analyses have been calculated for the bridge-based micro calorimeter with different sample thermal conductivities and heat capacities. The simulation results indicate that for the bridge-based microcalorimeter using pulse calorimetry, when the heat capacity of the sample film is close to or larger than the heat capacity of an empty calorimeter, the differential method of getting the sample heat capacity from the difference between a micro calorimeter with and without the sample is no longer suitable because the heat transfer and temperature distributions of the two calorimeters are no longer comparable to each other.

Copyright © 2009 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In