0

Full Content is available to subscribers

Subscribe/Learn More  >

A Surface-Directed Microfluidic Scheme for Parallel Nanoliter PCR Array Suitable for Point-of-Care Testing

[+] Author Affiliations
Naveen Ramalingam, Long-Qing Chen, Xin-Hao Yang, Liqun Deng, Qing-Hui Wang, Chiew Hoon Neo, Hai-Qing Gong

Nanyang Technological University, Singapore

Eric Yap Peng Huat

Defense Medical and Environmental Research Institute, Singapore

Paper No. ICNMM2009-82052, pp. 1007-1013; 7 pages
doi:10.1115/ICNMM2009-82052
From:
  • ASME 2009 7th International Conference on Nanochannels, Microchannels, and Minichannels
  • ASME 2009 7th International Conference on Nanochannels, Microchannels and Minichannels
  • Pohang, South Korea, June 22–24, 2009
  • Conference Sponsors: Nanotechnology Institute
  • ISBN: 978-0-7918-4349-9 | eISBN: 978-0-7918-3850-1
  • Copyright © 2009 by ASME

abstract

In resource-limited settings, it is impractical to get access to a diagnostic laboratory having sophisticated instruments, and it is desirable to use disposable point-of-care diagnostic chips that do not require liquid handling or pumping instruments for sample distribution among an array of reactors. In addition to the pump-less sample loading method, the challenge to seal an array of reactors without the use of microvalves or mechanical parts still persists. Implementation of microvalve array adds complexity to the chip fabrication and operation processes, and also reduces the space on the microchip. In this paper, we report the development of a high-throughput quantitative PCR chip platform for parallel analyses of multiple gene targets. The PCR mixture distribution among an array of 80 microreactors and subsequent isolation of the reactors were solely realized by a two-step surface tension-based microfluidic scheme, which eliminates the use of pumps, valves and liquid handling instruments. Confinement of the PCR mixture inside the micro reactors was achieved by implementing hybrid flow-restriction passive valves. The microreactors were isolated from each other by the flow of a curable liquid sealant delivered through microchannels by capillary action. We also investigated the effect of detergents that are present in most commercial PCR buffers. Presence of detergents makes the PCR buffer much more wetting on the passive capillary valve surface and this imposes another challenge to the design of the conventional hydrophobic patch valves which has been successfully used for deionized water. We demonstrated a successful capillary valve array with a common air venting channel having a hydrophobic surface for restricting the flow of PCR buffer containing surfactant. The interconnected microreactor array was fabricated on a glass chip substrate with approximate volume of 250 nl microreactor volume for PCR. A different set of PCR primers were preloaded into different microreactor on the PCR array chip for simultaneous amplification of multiple genes. Fluorescent signals from all the microreactors were simultaneously detected at every PCR thermal cycle using EvaGreen fluorescent dye on an in-house real-time PCR instrument. The capability of the scalable PCR array chip was demonstrated by amplifying a fragment of uidA gene for beta-glucuronidase of E. coli genome. Key technical issues related to chip operation such as PCR inhibition on the acid-washed glass substrate, and PCR compatibility of the sealant in both the uncured and cured states have been addressed.

Copyright © 2009 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In