Evaluation of a Tapered Header Configuration to Reduce Flow Maldistribution in Minichannels and Microchannels

[+] Author Affiliations
V. V. Dharaiya, A. Radhakrishnan, S. G. Kandlikar

Rochester Institute of Technology, Rochester, NY

Paper No. ICNMM2009-82288, pp. 771-777; 7 pages
doi:10.1115/ICNMM2009-82288
From:
  • ASME 2009 7th International Conference on Nanochannels, Microchannels, and Minichannels
  • ASME 2009 7th International Conference on Nanochannels, Microchannels and Minichannels
  • Pohang, South Korea, June 22–24, 2009
  • Conference Sponsors: Nanotechnology Institute
  • ISBN: 978-0-7918-4349-9 | eISBN: 978-0-7918-3850-1
  • Copyright © 2009 by ASME

abstract

In designing a heat exchanger, it is generally assumed that the fluid is uniformly distributed through the heat exchanger core. In reality, the flow distribution is rarely uniform due to inlet and outlet header designs and flow velocity changes in the headers. The flow distribution through a plate-fin heat exchanger (straight Z-type flow) with parallel microchannels and minichannels is studied by using a Computational Fluid Dynamics (CFD) code FLUENT. It was found that the flow maldistribution is quite severe with constant cross-sectional area headers. A modified header design with tapered cross-section was employed and the flow and pressure distributions were investigated using the CFD model. Further, a mathematical model was used to study the effect of the tapered headers on the pressure difference available for each channel across its inlet and outlet ends. The pressure difference across each channel is responsible for the actual flow rate through the channel. Results from the CFD were compared with the model predictions.

Copyright © 2009 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In