MEMS Based Dew Point Hygrometer With Optimal Self Adjusted Detection Threshold

[+] Author Affiliations
Ryszard Jachowicz, Jerzy Weremczuk, Daniel Paczesny, Grzegorz Tarapata

Warsaw University of Technology, Warsaw, Poland

Paper No. MicroNano2008-70134, pp. 137-142; 6 pages
doi:10.1115/MicroNano2008-70134
From:
  • 2008 Second International Conference on Integration and Commercialization of Micro and Nanosystems
  • 2008 Second International Conference on Integration and Commercialization of Micro and Nanosystems
  • Clear Water Bay, Kowloon, Hong Kong, June 3–5, 2008
  • Conference Sponsors: Nanotechnology Institute
  • ISBN: 0-7918-4294-0 | eISBN: 0-7918-3819-6
  • Copyright © 2008 by ASME

abstract

A new system of dew point temperature hygrometer, based on semiconductor MEMS detector is presented in the paper. Many details of MEMS detector construction are given with details in the report. Basic idea of algorithms of detector control is also discussed. More attention is devoted to subalgorithm for self-adjusted detector threshold operation. Excellent dynamic parameters of the new hygrometer (i.e. 2÷5 dew point detections and temperature measurements per second), proved by the hygrometer tests, will be presented and described in the report. It means that presented hygrometer is 10÷100 times faster than conventional hygrometers. In the end of the paper two medical applications are demonstrated with clinical test results. The first application is for dermatology for TransEpidermal Water Loss (TEWL) factor of human skin. The second is focused on measurement of humidity in human nose cavity and human throat during breathing. In both case fast humidity measurements, with time constant of some 0.5s, have been required.

Copyright © 2008 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In