Effect of Diffuser Contraction for a Centrifugal Compressor

[+] Author Affiliations
Kyung-Jun Kang, You-Hwan Shin, Kwang-Ho Kim, Yoon-Pyo Lee

Korea Institute of Science and Technology, Seoul, Republic of Korea

Paper No. FEDSM-ICNMM2010-30944, pp. 785-791; 7 pages
doi:10.1115/FEDSM-ICNMM2010-30944
From:
  • ASME 2010 3rd Joint US-European Fluids Engineering Summer Meeting collocated with 8th International Conference on Nanochannels, Microchannels, and Minichannels
  • ASME 2010 3rd Joint US-European Fluids Engineering Summer Meeting: Volume 1, Symposia – Parts A, B, and C
  • Montreal, Quebec, Canada, August 1–5, 2010
  • Conference Sponsors: Fluids Engineering Division
  • ISBN: 978-0-7918-4948-4 | eISBN: 978-0-7918-3880-8
  • Copyright © 2010 by ASME

abstract

This study will be described details on influence of movable diffuser such as local reverse flow patterns and pressure fluctuation in a vaneless diffuser during unstable operation of a centrifugal compressor. The experimental study is carried out in centrifugal compressor immersed into a water reservoir. Particle Image Velocity (PIV) is used to observe a secondary flow pattern and pressure transducer is used for investigating the onset and development of rotating stall inside vaneless diffuser. The reverse flow zone observes near hub wall of impeller exit at relatively low flow rate. This reverse flow on hub side wall brings about the rotating stall. This paper be simultaneously discussed on the effects of diffuser contraction to remove local reverse flow zone near hub wall, which are including variation of flow field in a vaneless diffuser and the influence on the pressure fluctuation. A contraction due to movable diffuser three cases (40%, 53% and 86% of diffuser width) was inserted into vaneless diffuser from a shroud wall. According to the results, the rotating stall involving single and two cells is enveloped by the outer lobe of the Rossby wave. Under the rotating stall onset, the stall propagation rate is 1.25Hz, 25% of the impeller speed in the same direction as the impeller in case of no contraction. In case of 40% contraction, onset of rotating stall is not delayed. In contrast of that, onset of rotating stall is delayed in case of 53%, 87% contraction. There exist several secondary vortices inside vaneless diffuser under onset of rotating stall. The size and location of them vary as flow rate decreases.

Copyright © 2010 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In