Performance Prediction of a Single-Zone Vertical Feedwater Heater

[+] Author Affiliations
Eric Svensson

Powerfect, Inc., Brick, NJ

William Mirowski

MidWest Generation, Waukegan, IL

Paper No. POWER2010-27105, pp. 147-152; 6 pages
doi:10.1115/POWER2010-27105
From:
  • ASME 2010 Power Conference
  • ASME 2010 Power Conference
  • Chicago, Illinois, USA, July 13–15, 2010
  • Conference Sponsors: Power Division
  • ISBN: 978-0-7918-4935-4 | eISBN: 978-0-7918-3876-1
  • Copyright © 2010 by ASME

abstract

This paper represents a case study of a replacement single-zone vertical feedwater heater with a pump forward drains system. When replacing a feedwater heater, it is important to review, evaluate and adjust the NLL of the new heater since it may not be the same as the NLL of the existing heater in order to achieve the same performance, particularly when changing the tube material. This paper strives to explain a method that was used in order to predict changes in both the feedwater and drains outlet temperatures based on varying liquid level. Single-zone feedwater heaters are typically sized and rated with a drains outlet temperature that is equal to the saturation temperature of the incoming bleed steam. Depending on the normal liquid level (NLL) setpoint, there is some subcooling that occurs due to the submerged tube surface that is typically not accounted for in the heater rating, this is especially true in a vertical channel down configuration. The outlet drains of a condensing zone only heater are still required to be safely transported in the liquid state to either another heater or to the condenser, therefore an adequate amount of subcooling is desired in order to preclude flashing and two-phase flow from occurring within the drains piping. The amount of subcooling that can be expected is related to the amount of surface that is submerged and therefore is directly tied to the liquid level inside the heater. Intuitively, more subcooling can be achieved by raising the liquid level; however, this has the effect of reducing the surface area available for condensation and ultimately the feedwater outlet temperature. In a pump forward drains system, this has an additional negative effect in that the drains are then combined with the outlet feedwater and reduces the feedwater temperature further prior to entering the next heater. It was desired to optimize the normal liquid level such that the drains outlet temperature would be subcooled enough to protect the downstream heater drain pump, but not to raise the level to a point that would significantly lower the inlet temperature to the next feedwater heater, resulting in inefficiencies in the overall heat cycle and overloading the downstream heater.

Copyright © 2010 by ASME
Topics: Feedwater

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In