The Mathematical Model of a Procedure for Percutaneous Annuloplasty

[+] Author Affiliations
Toufic Azar, Jorge Angeles, Jozsef Kövecses

McGill University, Montreal, QC, Canada

Renzo Cecere

McGill University Health Center, Montreal, QC, Canada

Paper No. DETC2010-28916, pp. 1219-1224; 6 pages
doi:10.1115/DETC2010-28916
From:
  • ASME 2010 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
  • Volume 1: 36th Design Automation Conference, Parts A and B
  • Montreal, Quebec, Canada, August 15–18, 2010
  • Conference Sponsors: Design Engineering Division and Computers in Engineering Division
  • ISBN: 978-0-7918-4409-0 | eISBN: 978-0-7918-3881-5
  • Copyright © 2010 by ASME

abstract

Existing mathematical models of the mitral valve allow the simulation of ring open-heart annuloplasty procedures intended to reduce the lumen of the valve. Using these models, only a posteriori effects can be predicted. With the advent of novel percutaneous annuloplasty approaches, there is a need to describe a priori effects; in particular, this paper focuses on a technique which consists of sequentially installing interconnected anchors around the mitral annulus, whose lumen is reduced by the tightening of the tethered wire. We develop here a static mathematical model of the mitral annulus that takes into account the mechanical response of its tissue and the surrounding muscular tissue. A number of roughly coplanar points corresponding to anchor positions, at about equal distantes, are identified on the annulus. Each of these points is then attached to a linearly elastic spring of a given stiffness, The spring-end is connected to a fixed pinned support, the other end supporting the wire, that forms a loop. With this model we estimate the anchor-points position vectors after lumen reduction and the wire tension that is needed to reduce the perimeter of the polygon defined by the anchor points to a given value, which, for each patient, is related to the desired lumen. This formulation leads to the minimization of the potential energy of the mechanical system over the position vectors of the anchor points after tightening, which are the design variables. These are found by solving the first-order normality conditions of the equality-constrained optimization problem. Preliminary experimental data obtained on cadaveric swine hearts validate the model: it can be used to predict, for a given perimeter size reduction, the wire tension as well as the anchor position after repair.

Copyright © 2010 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In