Analysis of Airflow Distribution Across a Front-to-Rear Server Rack

[+] Author Affiliations
Amir Radmehr, Kailash C. Karki, Suhas V. Patankar

Innovative Research, Inc., Plymouth, MN

Paper No. IPACK2007-33574, pp. 837-843; 7 pages
doi:10.1115/IPACK2007-33574
From:
  • ASME 2007 InterPACK Conference collocated with the ASME/JSME 2007 Thermal Engineering Heat Transfer Summer Conference
  • ASME 2007 InterPACK Conference, Volume 1
  • Vancouver, British Columbia, Canada, July 8–12, 2007
  • Conference Sponsors: Electronic and Photonic Packaging Division
  • ISBN: 0-7918-4277-0 | eISBN: 0-7918-3801-3
  • Copyright © 2007 by ASME

abstract

The most common server racks in data centers are front-to-rear racks, which draw in the cooling air from the front side and discharge it from the backside. In a raised-floor data center the cooling air to these racks is provided by perforated tiles that are placed in front of them. In a high-density data center, these tiles discharge a considerable amount of airflow, which leads to a high-velocity vertical jet in front of the rack. Such a high-velocity jet may bypass the servers located at the bottom of the rack leading to their airflow starvation and potential failure. In this paper the effect of the high-velocity jet on the airflow taken by servers at various heights in the rack is studied. A computer model based on the Computational Fluid Dynamics (CFD) technique is used to predict the airflow distribution through servers stacked in the rack. Two cases are considered. In one case, the rack is placed in the middle of a row of racks in a prefect hot aisle-cold aisle arrangement. The boundary conditions around such a rack is symmetrical. In the other case, the rack is placed in a room with asymmetrical boundary conditions. The characteristics of the servers in the rack are taken from typical 1U and 2U servers manufactured by IBM. It is shown that in general the high-velocity jet has a mild effect on the airflow taken by the servers, and the airflow reduction is limited to servers at the bottom of the rack. Racks in a symmetrical configuration are more susceptible to the airflow starvation. In the most critical conditions, an airflow reduction of 15% is calculated for the server located at the bottom of the rack. Using the result obtained from the computational analysis, a simple model is developed to predict the reduction of the cooling air under the most critical situation for the server placed at the bottom of the rack.

Copyright © 2007 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In