0

Full Content is available to subscribers

Subscribe/Learn More  >

Effect of Head Surface Roughness and Sterilization Method on Wear of UHMWPE Acetabular Cups: Preliminary Hip Joint Simulator Results

[+] Author Affiliations
Anneli Jedenmalm

Royal Institute of Technology, Stockholm, Sweden

Walther Leardini, Mara Zavalloni, Saverio Affatato

Istituti Ortopedici Rizzoli, Bologna, Italy

Paper No. ESDA2006-95512, pp. 953-961; 9 pages
doi:10.1115/ESDA2006-95512
From:
  • ASME 8th Biennial Conference on Engineering Systems Design and Analysis
  • Volume 3: Dynamic Systems and Controls, Symposium on Design and Analysis of Advanced Structures, and Tribology
  • Torino, Italy, July 4–7, 2006
  • ISBN: 0-7918-4250-9 | eISBN: 0-7918-3779-3
  • Copyright © 2006 by ASME

abstract

More than one million hip joint replacements are performed each year in the world. However, the implants do not last forever due to material limitations, even though the operation is successful. The most common material combination used today is a CoCr head articulating against an UHMWPE (Ultra High Molecular Weight Polyethylene) acetabular cup. Several investigations have shown that the metal head is roughened inside the body and thus accelerating wear of the polymer cup. The sterilization method is also known to have effect on the wear properties. In vitro wear tests are however usually performed with as new implants. This investigation aimed at study the impact of head surface roughness on wear of both sterilized and non-sterilized acetabular cups. A total of nine acetabular cup and head pairs were wear tested in a hip joint simulator for 2Million cycles (Mc) with bovine calf serum as lubricant. Wear was determined by weighing of all cups. The heads were of CoCrMo and the average initial head surface roughness was 15nm (Ra ), measured with a white light interference profilometer. The roughening was produced with a SiC paper producing circular multidirectional wear tracks to a surface roughness of about 400nm (Ra ). The cups were of UHMWPE and the sterilized cups were 3Mrad gamma-radiated in nitrogen. The surface roughness after wear test was unchanged for the roughened heads, while the initially smooth heads were slightly roughened. Preliminary results show that the rough heads increase the wear of the cups 2-fold. The γ-irradiation affected both wear- and soak rate.

Copyright © 2006 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In