0

Full Content is available to subscribers

Subscribe/Learn More  >

A Device to Test the Primary Stability in Cementless Hip Arthroplasty Through Mechanical Vibrations

[+] Author Affiliations
Elena Varini, Ewa Bialoblocka, Luca Cristofolini

Istituti Ortopedici Rizzoli, Bologna, Italy

Maurizio Lannocca, Angelo Cappello

University of Bologna, Bologna, Italy

Paper No. ESDA2006-95185, pp. 423-430; 8 pages
doi:10.1115/ESDA2006-95185
From:
  • ASME 8th Biennial Conference on Engineering Systems Design and Analysis
  • Volume 2: Automotive Systems, Bioengineering and Biomedical Technology, Fluids Engineering, Maintenance Engineering and Non-Destructive Evaluation, and Nanotechnology
  • Torino, Italy, July 4–7, 2006
  • ISBN: 0-7918-4249-5 | eISBN: 0-7918-3779-3
  • Copyright © 2006 by ASME

abstract

Primary stability of cementless prostheses is critical for the long term outcome of the operation. Cementless implants are mechanically stabilized during surgery through a press-fitting procedure. To achieve a good initial stability, it is important that the surgeon performs an optimal press-fitting, avoiding both problems of stem loosening, and micro-cracking of the host bone. A possible approach to solve this problem and assist the surgeon in achieving the optimal compromise, involves the use of the vibration analysis. This technique was used in the presented study, which was aimed to design and test a prototype device able to evaluate the primary stability of a cementless prosthesis, at the femoral level. In particular, the goal was to discriminate between stable and quasi-stable implants; thus the stem-bone system was assumed linear in both cases. For that reason, it was decided to study the frequency responses of the system, instead of the harmonic distortion. The prototype was developed. It is mainly composed by a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on a composite femur implanted with a conventional stem. The results showed that the input signal is repeatable and the output can be accurately recorded. The parameters that seem to be more sensitive to stability are the resonance frequency and the amplitude at the resonance frequency.

Copyright © 2006 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In