0

Full Content is available to subscribers

Subscribe/Learn More  >

Design, Build, and Test of a Permanently Implanted Prosthetic Hand

[+] Author Affiliations
Matthew Williams, Wayne Walter

Rochester Institute of Technology, Rochester, NY

Paper No. IMECE2002-33018, pp. 345; 1 page
doi:10.1115/IMECE2002-33018
From:
  • ASME 2002 International Mechanical Engineering Congress and Exposition
  • Advances in Bioengineering
  • New Orleans, Louisiana, USA, November 17–22, 2002
  • Conference Sponsors: Bioengineering Division
  • ISBN: 0-7918-3650-9 | eISBN: 0-7918-1691-5, 0-7918-1692-3, 0-7918-1693-1
  • Copyright © 2002 by ASME

abstract

The feasibility of a permanently implanted prosthetic hand was evaluated from both an internal biocompatibility and exterior mechanics point of view. A literature review of the issues involved in permanent implantation of a percutanious device was performed in the areas of bone interaction and fixation and neural interface control. A theoretical implant was designed for a 90th percentile male, using a HA-G-Ti composite material to provide a permanent base to which the hand could attach. Using a radial implant length of 1.87 inches and an ulna implant length of 1.32 inches, the simulated implant could withstand a push out force of 10.260 pounds. Using nerve guidance channels and microelectrode arrays, a Regenerative Neural Interface was postulated to control the implant. The use of Laminin-5 was suggested as a method of preventing the lack of wound closure observed in percutanious devices. The exterior portion of a permanent artificial hand was analyzed by the construction of a robotic hand optimized for weight, size, grip force and wrist torque, power consumption and range of motion. Using a novel dual drive system, each finger was equipped with both joint position servos as well as a tendon. Fine grip shape was formed using the servos, while the tendon was pulled taunt when grasping an object. Control of the prosthetic hand was performed using a distributed network of micro-controllers. Each finger’s behavior was governed by a master/slave system where input from a control glove was processed by a master controller with joint servo and tendon instructions passed to lower-level controllers for management of hand actuators. The final weight of the prototype was 3.85 pounds and was approximately 25% larger than the 90th percentile male hand it was based on. Grip force was between 1.25 and 2 pounds per finger, depending on amount of finger flexion with a wrist lifting torque of 1.2 pounds at the center of the palm. The device had an average current draw of 3 amps in both normal operation and tight grasping. Range of motion was similar to that of the human model. Overall feasibility of the device is examined and factors involved in industrial implementation are discussed.

Copyright © 2002 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In