0

Full Content is available to subscribers

Subscribe/Learn More  >

Wet SMA Actuator Array With Matrix Vasoconstriction Device

[+] Author Affiliations
Leslie Flemming

North Dakota State University

Stephen Mascaro

University of Utah

Paper No. IMECE2005-82952, pp. 1751-1758; 8 pages
doi:10.1115/IMECE2005-82952
From:
  • ASME 2005 International Mechanical Engineering Congress and Exposition
  • Dynamic Systems and Control, Parts A and B
  • Orlando, Florida, USA, November 5 – 11, 2005
  • Conference Sponsors: Dynamic Systems and Control Division
  • ISBN: 0-7918-4216-9 | eISBN: 0-7918-3769-6
  • Copyright © 2005 by ASME

abstract

A new mechanism for controlling arrays of Shape Memory Alloy (SMA) muscle wires has been developed. Similar to previous work, SMA wires on the order of 0.25 mm in diameter are embedded in a network of compliant fluid filled vessels on the order of 1 mm in diameter. Hot and cold water are delivered through the vascular network to convectively heat and cool the SMA muscles, causing them to contract and extend. By arranging the muscles or actuators in a 2D array, n2 actuators can be controlled using 2n valves, where the valves control the flow to and from rows and columns of actuators. However, unlike the previous Matrix Manifold and Valve system (MMV), the fluid flows to the actuators are now controlled using a Matrix Vasoconstriction Device (MVD). The MVD is capable of constricting combinations of the vessels, which are arranged in rows and columns. The MVD does not introduce any fluidic resistance to the network until constricted, allowing for larger flow rates and faster muscle cycling. The MVD system architecture also removes undesired dynamic effects stemming from fluidic capacitance which were suffered by the MMV. An array of 16 muscle wires has been experimentally implemented using an MVD with 8 control inputs. The MVD has been constructed in a 50 mm × 50 mm × 60 mm volume, and the overall length of the actuators is 500 mm. The system will drive each SMA wire at a rate of 2 Hz with a force of 10 N and a stroke of 10 mm. The system could control a robotic hand with up to 16 DOF and fit within the size of a human forearm.

Copyright © 2005 by ASME
Topics: Actuators

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In