0

Full Content is available to subscribers

Subscribe/Learn More  >

Diode-Laser-Based Sensor Measurements of Nitric Oxide and Carbon Monoxide in Combustion Exhaust Streams

[+] Author Affiliations
Thomas N. Anderson, Rodolfo Barron-Jimenez, Jerald A. Caton

Texas A&M University, College Station, TX

Robert P. Lucht

Purdue University, West Lafayette, IN

Sukesh Roy, Michael S. Brown

Innovative Scientific Solutions, Inc., Dayton, OH

James R. Gord

Air Force Research Laboratory, Wright-Patterson AFB, OH

Thomas Walther

Darmstadt University of Technology, Darmstadt, Germany

Ian Critchley, Luis Flamand

Honeywell Engines and Systems, Phoenix, AZ

Paper No. HT2003-47532, pp. 185-190; 6 pages
doi:10.1115/HT2003-47532
From:
  • ASME 2003 Heat Transfer Summer Conference
  • Heat Transfer: Volume 2
  • Las Vegas, Nevada, USA, July 21–23, 2003
  • Conference Sponsors: Heat Transfer Division
  • ISBN: 0-7918-3694-0 | eISBN: 0-7918-3679-7
  • Copyright © 2003 by ASME

abstract

All-solid-state continuous-wave (cw) laser systems for ultraviolet (UV) absorption measurements of the nitric oxide (NO) molecule and mid-infrared (IR) absorption measurements of carbon monoxide (CO) were developed and demonstrated. For the NO sensor, 250 nW of tunable cw UV radiation at 226.8 nm is produced by sum-frequency-mixing in a beta-barium borate crystal. For the CO sensor, 2μW of tunable cw IR radiation at 4.5 μm is produced by difference-frequency mixing in a periodically-poled lithium niobate crystal. A tunable external-cavity diode laser (ECDL) provides one of the fundamental beams for both processes so that the wavelength of the generated UV/IR can be tuned over NO/CO absorption lines to produce a fully resolved absorption spectrum. The sensors were used for measurements in the exhaust stream of an operating auxiliary power unit (APU) gas turbine engine and a well-stirred reactor (WSR). During these tests, NO was measured in the exhaust at levels below 10 ppm. For measurements at levels above 20 ppm, the NO emission levels obtained using the new sensor agreed with the results of probe sampling chemiluminescent analyzer results to within 10%. A detection limit of 0.8 ppm of per meter path length at 1000 K is estimated for the NO sensor. Measurements with the CO sensor demonstrated an agreement with extractive probe sampling to within 15%. The estimated detection limit of the CO sensor is a few ppm per meter path length at 1000 K.

Copyright © 2003 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In