Four Years of Successful Operation at Mercer Generating Station Following Feedwater Heater Tube Repair: An Alternative to Replacement

[+] Author Affiliations
Bruce W. Schafer

Framatome ANP, Lynchburg, VA

Daniel B. Patten, Charles R. McCall

PSEG Power LLC, Newark, NJ

Paper No. IJPGC2003-40067, pp. 61-69; 9 pages
doi:10.1115/IJPGC2003-40067
From:
  • International Joint Power Generation Conference collocated with TurboExpo 2003
  • 2003 International Joint Power Generation Conference
  • Atlanta, Georgia, USA, June 16–19, 2003
  • Conference Sponsors: Power Division
  • ISBN: 0-7918-3692-4 | eISBN: 0-7918-3677-0
  • Copyright © 2003 by ASME

abstract

In the late 1990’s, two of the high-pressure feedwater heaters at PSEG Power LLC’s Mercer Generating Station began to experience tube leaks after almost 40 years of operation. Prior to the repair, these leaks were occurring at least once per month. Based on eddy current and video probe inspections, the area of tube degradation appeared to be isolated to the desuperheater region of the bundle. PSEG Power LLC performed a life assessment of the feedwater heaters and, based on the good condition of the remainder of the heaters, determined that repair of the desuperheater region could improve the reliability and significantly extend the operating life of the heat exchangers. The heater condition, coupled with a repair vs. replace economic model, led to the decision to sleeve the feedwater heaters. During the April 1999 maintenance outage, Framatome ANP performed repair work on the two high pressure feedwater heaters. This repair consisted of installing an 11 foot-2 inch (3404 mm) sleeve in all outlet tube ends, spanning the desuperheating region. The sleeving method used consisted of a three step process. After the sleeve was installed, its lower end was roll expanded within the tubesheet. Next, the entire length of the sleeve in the desuperheater section was expanded into close contact with the parent tube. The final installation step was upper hydraulic expansions, above the desuperheating zone end plate, in nondefective portions of the tube. This installed sleeve became the pressure boundary in the desuperheater section of the feedwater heater. After more than 4 years of operation, no tube leaks have been noted and the need to replace the components has been eliminated for the foreseeable future.

Copyright © 2003 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In