abstract

This work intended to evaluate the instantaneous vapour fraction in the turbo-pump inducer of a liquid propellant rocket engine. Experimentations held on an experimental pump test facility and cavitation was attained by reducing the inlet pressure in the machine while maintaining constant the inducer rotational speed. Measurements of vapour fraction through the rotating inducer were achieved by means of an x-ray-based system. The system exerted an industrial x-ray generator and 10 collimated scintillation detectors. Detectors were functioning in current mode thus permitting an acquisition at 5 kHz for each detector. A reference x-ray detector situated between the x-ray generator and the machine permitted the treatment of x-ray beam energy fluctuations related to industrial generators [1, 2, 3]. Acquisitions were performed in three axial positions on the inducer. For each measurement position, three cavitation sequences with different flow rate conditions (Q/Qn = 0.9, 1, 1.1, where Qn is the nominal flow rate) were accomplished. Each cycle is performed by decreasing gradually the pressure while maintaining an imposed rotational speed of 4000 rpm. Each test is constituted of 10 pressure points varying from 2.40 to 0.48 bars representing a complete cavitation sequence. X-ray acquisition was performed for each pressure point and it was carried out for 10 seconds thus corresponding to 667 tours of the inducer. Vapour fraction was determined instantaneously thus showing the applicability and the precision of the method in such measurements despite of the geometry and rotation speed constraints. Consequently a quantitative and qualitative evaluation of the vapour fraction is presented. Results show that the vapour distribution is well related to cavitation development on the blades of the inducer for steady cavitation condition.

Copyright © 2005 by ASME
Topics: X-rays

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In