A Novel Vibrating Ribbon Technique

[+] Author Affiliations
Jonathan H. Watmuff

RMIT University, Bundoora, VIC, Australia

Paper No. FEDSM2005-77323, pp. 1673-1678; 6 pages
doi:10.1115/FEDSM2005-77323
From:
  • ASME 2005 Fluids Engineering Division Summer Meeting
  • Volume 1: Symposia, Parts A and B
  • Houston, Texas, USA, June 19–23, 2005
  • Conference Sponsors: Fluids Engineering Division
  • ISBN: 0-7918-4198-7 | eISBN: 0-7918-3760-2
  • Copyright © 2005 by ASME

abstract

A novel vibrating ribbon apparatus is described that is active over the full span of a wind tunnel test section. The spanwise uniformity of the vibration amplitude and other ribbon characteristics are considered in detail. The height of each end of the ribbon above the test plate can be adjusted in situ, while the ribbon is vibrating and with flow in the test section, thereby allowing the response of the layer to be easily tuned. The growth of the wave amplitude downstream of the ribbon is shown to agree with numerical predictions. However, two or three wavelengths of development are required before the wave amplitude follows the predicted growth. The flow around an inactive ribbon is examined using a commercial CFD solver and features such as a miniature separation bubble just downstream of the ribbon are revealed. The distance required for the mean flow to recover from the disturbance introduced by the ribbon is greater when the ribbon is located further from the wall. The mean flow recovers to form a boundary layer that is slightly thicker than the undisturbed flow. Experimental measurements indicate that the distance required for the wave motions to follow predicted behavior is about 4 or 5 times larger than distance for recovery of the mean flow.

Copyright © 2005 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In