Optimizing Electrical Protection for Medium Voltage Controller Lineup to Improve Liquids Pipelines Operation Reliability and Safety

[+] Author Affiliations
Ting Yu, Tushar Chaitanya

Enbridge, Inc., Edmonton, AB, Canada

Paper No. IPC2018-78117, pp. V003T04A041; 10 pages
doi:10.1115/IPC2018-78117
From:
  • 2018 12th International Pipeline Conference
  • Volume 3: Operations, Monitoring, and Maintenance; Materials and Joining
  • Calgary, Alberta, Canada, September 24–28, 2018
  • Conference Sponsors: Pipeline Division
  • ISBN: 978-0-7918-5188-3
  • Copyright © 2018 by ASME

abstract

MV (Medium Voltage) controller lineup electrical protection is crucial in protecting the equipment from large scale damage upon the occurrence of an electrical fault, reducing the time to restore power, thereby minimizing the impact to liquids pipelines operation. The paper discusses typical electrical failure modes that may occur in MV controller lineups, and demonstrates practical relaying engineering techniques that enable fast and effective fault clearing. Electrical faults in the MV controller lineup are often arcing type, commonly involve ground. Mitigating arc hazards in MV Class E2 controller lineups has traditionally been challenging without sacrificing the protection selectivity. As the paper demonstrates, a relaying scheme with the combined use of high-speed light-sensing and overcurrent detection will effectively mitigate the incident energy, while maintaining the protection selectivity for non-arcing overcurrent events.

For new MV controller lineups, in addition to the “high-speed light detection and fault interruption”, zone-selective interlocking (ZSI) can also be a practical solution in improving relay protection speed, thus reduce the chance of severe arc flash occurrences. ZSI is particularly effective for fault occurrences on the line side of the phase CTs, busways or main incoming circuits. The ZSI scheme can be implemented on both Class E2 and circuit breaker (VCB) type MV controller lineups, however, with slightly different trip logic due to the limited fault clearing capability of the contactor.

Although there are multiple contributing factors, the direct causes of electrical failures in MV controller lineup are commonly related to improper power cable installation and handling, potentially leading to premature insulation breakdown due mainly to the proximity effect and/or partial discharge. Inadequate cable separation and prolonged fault trip delay can increase the possibility of arcing fault occurrence. This can usually be mitigated through appropriate cable spacing, adequate conductor insulation, and optimized fault detection schemes. The paper provides overviews of the mechanisms of proximity effect and partial discharge propagation, and the modern relaying approaches for accurate fault type discrimination and facilitating fast fault interruption.

Two case studies are provided in the paper as an aid in understanding the electrical fault mechanism originated from cable insulation failure, demonstrating the incident energy reduction before and after the implementation of high-speed light detection and fault interruption solutions on an existing MV controller lineup.

Copyright © 2018 by ASME

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In