Thermal storage systems were originally designed to shift on-peak cooling production to off-peak cooling production in order to reduce on-peak electricity demand. Recently, however, the reduction of both on- and off-peak demand is a critical issue. Reduction of on- and off-peak demand can also extend the life span and defer or eliminate the replacement of power transformers. Next day electricity consumption is a critical set point to operate chillers and associated pumps at the appropriate time. In this paper, a data evaluation process using the annual daily average cooling consumption of a building was conducted. Three real-time building load forecasting models were investigated: a first-order autoregressive model (AR(1)), an autogressive integrated moving average model (ARIMA(0,1,0)), and a linear regression model. A comparison of results shows that the AR(1) and ARIMA(0,1,0) models provide superior results to the linear regression model, except that the AR(1) model has a few unacceptable spikes. A complete control algorithm integrated with a corrected AR(1) forecast model for a chiller plant including chillers, thermal storage system, and pumping systems was developed and implemented to verify the feasibility of applying this algorithm in the building automation system. Application results are also introduced in the paper.

References

1.
Tamblyn
,
R. T.
, 1985, “
Control Concept for Thermal Storage
,”
ASHRAE Trans.
,
91
(
1B
), pp.
5
11
.
2.
Braun
,
J. E.
, 1990, “
Reducing Energy Costs and Peak Electrical Demand Through Optimal Control of Building Thermal Mass
,”
ASHRAE Trans.
,
96
(
2
), pp.
876
888
.
3.
Wei
,
G.
,
Liu
,
M.
,
Sakurai
,
Y.
,
Claridge
,
D.
, and
Turner
,
W. D.
, 2002, “
Practical Optimization of Full Thermal Storage Systems Operation
,”
ASHRAE Trans.
,
108
(
2
), pp.
360
368
.
4.
Massie
,
D. D.
,
Kreider
,
J. F.
, and
Curtiss
,
P. S.
, 2004, “
Verification of a Neural Network-Based Controller for Commercial Ice Storage Systems
,”
ASHRAE Trans.
,
110
(
2
),
471
478
.
5.
Liu
,
S.
, and
Henze
,
G. P.
, 2007, “
Evaluation of Reinforcement Learning for Optimal Control of Building Active and Passive Thermal Storage Inventory
,”
J. Sol. Energy Eng.
,
29
, pp.
215
225
.
6.
Henze
,
G. P.
,
Krati
,
M.
, and
Brandemuehl
,
M. J.
, 1997, “
A Simulation Environment for the Analysis of Ice Storage Controls
,”
HVAC&R Res.
,
3
(
2
), pp.
128
148
.
7.
Henze
,
G. P.
,
Felsmann
,
C.
, and
Knabe
,
G.
, 2004, “
Evaluation of Optimal Control for Active and Passive Building Thermal Storage
,”
Int. J. Therm. Sci.
,
43
(
2
), pp.
173
183
.
8.
Henze
,
G. P.
,
Kalz
,
D. E.
, and
Liu
,
S.
, 2005, “
Experimental Analysis of Model-Based Predicative Optimal Control for Active and Passive Building Thermal Storage Inventory
,”
HVAC&R Res.
,
11
(
2
), pp.
189
214
.
9.
Zhou
,
J.
,
Wei
,
G.
, and
Turner
,
W. D.
, 2005, “
Control Optimization for Chilled Water Thermal Storage System Under Complicated Time-of-Use Electricity Rate Schedule
,”
ASHRAE Trans.
,
111
(
1
), pp.
184
195
.
10.
Seem
,
J. E.
, and
Braun
,
J. E.
, 1991, “
Adaptive Methods for Real-Time Forecasting of Building Electrical Demand
,”
ASHRAE Trans.
,
97
(
1
), pp.
710
721
.
11.
Montgomery
,
D. C.
,
Jennings
,
C. L.
, and
Kulahci
,
M.
, 2007,
Introduction to Time Series Analysis and Forecasting
,
John Wiley & Sons, Inc.
,
Hoboken, NJ
.
12.
Ljung
,
L.
, and
Söderström
,
T.
, 1987,
Theory and Practice of Recursive Identification
,
MIT Press
,
Cambridge, MA
.